Special features
• Graphic evaluation of actual
consumption, leakage, pressure, dew point,
current consumption
• Cost calculation of leakage and compressed
air contsumption
• User-specific analysis: Which plant uses how
much compressed air? |
|
| |
Technical Data |
 |
|
Dimensions: 92 x 92 x 55 mm, IP 65
(panel mounting)
inputs: 2 digital inputs for
VA 300 resp. FA 300
interface: USB, CS data collector
Keypad: 4 keys
Power supply: 90-260 VAC, 50-60 Hz
accuracy: See sensor data page 6
alarm outputs: 2 relays, 230 VAC, 3 A
analogue output: 2 x 4 ... 20 mA
application temp.: 0 ... 50 °C
Options
Wall housing: 118 x 115 x 93 mm, IP 65
Data logger: 500,000 measuring values
start-/stopzeit, measuring
rate freely adjustable
rs 485: up to 256 x DS 300 ,
connectable, evaluation at
PC via CS Soft in graphic and
table form |
| |
|
| |
Consumption |
 |
All relevant measuring data for an
economic operation of the compressed air line at a glance:
• Actual air consumption in m³/h
or m³/min
• Total air consumption in m³
• Pressure dew point in °Ctd
• Line pressure in bar
• Current consumption in A
• Temperature in °C
The data transfer to the PC is effected:
• by means of the CS data collector
(manually)
• via USB interface for short distance PC
to display DS 300
• via RS 485 interface for long distances
The CS data collector (USB) is able to:
• read out up to 64 x DS 300 at the PC
• evaluate data in the CS Soft Professional
• reprogram DS 300 |
| |
Technical Data |
|
Clamp-on Ammeter:
measuring range: 0 to 500 a
accuracy: ± 0.5 %
Dew pOint prOBe fa 300-2:
measuring range: -80 to 20 °ctd
accuracy: ± 2 °ctd at -40 °ctd
preSSUre prOBe:
measuring range: 0 to 6 bar
accuracy: ± 0,5 % |
|
| |
| |
|
|
|
|
|
|
| |
|
|